Loading scheduler…

Inside an AI-supported read.

Natoe’s remote radiology workflow connects your facility with our reading team. Study context, DXR drafting and report quality checks support each radiologist’s work.

From the study to the report

  1. 01

    Study context

    Generated three-view wrist image used to explain the reporting workflowXR LT WRIST 3V
    ImagesClinical historyAvailable priors
  2. 02

    DXR draft

    DICTATION

    Small nondisplaced dorsal distal ulnar fracture, age indeterminate. Mild first carpometacarpal osteoarthritis.

    STRUCTURED IMPRESSION

    1. Small nondisplaced dorsal distal ulnar fracture, age indeterminate. 2. Mild first carpometacarpal osteoarthritis.

  3. 03

    Quality review

    QUALITY CHECKS
    • Missing information
    • Conflicting statements
    • Exam mismatches
    FINDINGS ↔ IMPRESSION

    The distal ulnar fracture is included in both sections.

    Aligned · Ready for radiologist review

From study intake
to signed report.

Orchestration routes the study, assigns a reader and delivers the signed report. Rejections and addendum requests stay linked to the original case.

01Study received
02Reader assigned
03Report prepared & checked
04Radiologist signs
05Report delivered
Explore teleradiology solutions for your facility ↗

Compare with
the prior study.

Prior Cases Analysis summarizes the available history and compares findings by anatomical region and study date.

The radiologist can open the source report or image to check the comparison, using AI-supported decision support within the current study.

  • Summary across available prior cases
  • Region-by-region comparison
  • Source reports and images within reach

Inside Natoe · Prior comparison

Prior Cases Analysis with a summary and region-by-study comparison table

AI detects potential findings
Our radiologist reviews them

FDA-cleared AI algorithms analyze supported scans for potential abnormalities. The radiologist reviews the output alongside the full study, history and priors to make the final interpretation.

A supported study

Analysis depends on the study type and clinical indication.

Potential findings

An AI preliminary report surfaces findings for review; it is not the signed report.

The radiologist’s read

The reader checks the images and decides what belongs in the final report.

Inside Natoe · AI preliminary output

Natoe AI preliminary report viewer identifying its AI-generated status

From spoken findings
to a structured report.

Our radiologist dictates the abnormalities. DXR builds a complete structured draft, adding normal findings for the radiologist to review.

Natoe DXR XR LT WRIST 3V

Abnormal findings only

Mild degenerative changes involve the first carpometacarpal joint. A small ossific density with adjacent cortical irregularity is present along the dorsal distal ulna, visible only on the lateral view. Small nondisplaced dorsal distal ulnar fracture, age indeterminate. Mild first carpometacarpal osteoarthritis.

Ready for radiologist review

Radiologist findingsAI-added normal findings

FINDINGS

BONES

A small ossific density with adjacent cortical irregularity is present along the dorsal distal ulna, visible only on the lateral view, compatible with a small nondisplaced fracture of indeterminate age. No other fracture identified. Osseous alignment is maintained.

JOINTS

Mild first carpometacarpal osteoarthritis. The remaining joint spaces are maintained. No dislocation.

SOFT TISSUES

No adjacent soft tissue swelling.

IMPRESSION

1. Small nondisplaced dorsal distal ulnar fracture of indeterminate age. 2. Mild first carpometacarpal osteoarthritis.

Natoe DXR · XR LT WRIST 3V

Radiologist findingsAI-added normal findings

FINDINGS

BONES

A small ossific density with adjacent cortical irregularity is present along the dorsal distal ulna, visible only on the lateral view, compatible with a small nondisplaced fracture of indeterminate age. No other fracture identified. Osseous alignment is maintained.

JOINTS

Mild first carpometacarpal osteoarthritis. The remaining joint spaces are maintained. No dislocation.

SOFT TISSUES

No adjacent soft tissue swelling.

IMPRESSION

1. Small nondisplaced dorsal distal ulnar fracture of indeterminate age. 2. Mild first carpometacarpal osteoarthritis.

Report issues flagged
for the radiologist.

AI QA checks each radiologist-prepared report for missing information, contradictions and exam mismatches. The reader reviews the flag and decides whether a correction is needed.

REPORT QUALITY CHECK

  1. 01Review radiologist draft
  2. 02Flag the contradiction
  3. 03Radiologist assesses
FINDINGS

A small nondisplaced dorsal distal ulnar fracture, age indeterminate.

DRAFT IMPRESSION

No fracture identified.

Conflict with the findings

The radiologist reviews the flag and decides the correction.

Review the issue in the reporting workspace.

The flagged issue appears with the case. The radiologist can correct the report or assess whether the flag is a false positive.

87% of reviewed AI QA flags were confirmed correct by radiologists.

Clinical accountability at Natoe ↗

Inside Natoe · Validation review

Natoe reporting workspace showing a validation issue requiring radiologist review

Products for the
radiology community

Natoe DXR ↗

Spoken findings become an editable, structured report draft within the reading workflow.

Natoe Discover ↗

Explore radiology AI tools and the companies developing them.

See a case from intake to delivery.

Ask us to show prior comparison, dictation and a quality check using a study type you send.